Short answer: choose in this order — (1) confirm the SBS footprint, (2) pick the skirt type based on whether a robot handles the plate, (3) pick volume and format (0.1 mL vs 0.2 mL; single tubes vs strips vs plates), (4) pick the sealing film based on whether you read fluorescence, and (5) verify cleanliness (DNase/RNase-free) and instrument fit by model.
Getting the order right matters, because the first two constraints eliminate most of the catalogue before price is even a factor.
1. Start with the SBS footprint
SBS (Society for Biomolecular Sciences) defines the standard microplate footprint — outer dimensions and well positions. Two consequences:
- A plate that meets SBS will physically fit any SBS-compliant instrument.
- A plate that nearly meets SBS may still seat, but with uneven contact between wells and the thermal block. That shows up as inconsistent Ct values across a plate — you get data that looks plausible but is not reproducible.
SBS compliance is therefore non-negotiable, and it is the one specification worth verifying with the supplier’s own documentation rather than assuming.
2. Skirt type: what it is actually for
The skirt is the raised plastic edge around the plate. It is not cosmetic — it determines whether the plate can be handled by automation.
| Skirt type | Best for |
|---|---|
| Non-skirted | Manual pipetting only; lowest cost; unsuitable for robotic grippers and many plate stackers |
| Semi-skirted | A middle ground — enough edge for many handlers, while still fitting instruments with tight clearances |
| Fully skirted | Automated workstations, robotic arms and plate stackers; the most rigid and the least prone to warping |
Rule of thumb: if a robot touches the plate, use fully skirted. If the plate is handled by hand and the instrument has tight clearances, semi-skirted is usually the right compromise. Non-skirted is for manual, cost-sensitive work.
3. Volume and format
Plate well count
- 96-well — the default for most qPCR and endpoint PCR work.
- 384-well — for high-throughput screening and reagent-limited assays.
Tube format
- 0.1 mL — low-volume reactions; sits higher in the block and suits instruments designed for low-volume tubes.
- 0.2 mL — the most widely used size; the safe default.
- Single tubes — flexible, for ad-hoc or low-count reactions.
- 8-tube strips and 12-tube strips — the practical middle ground: fewer plastic items to handle than singles, less commitment than a full plate, and compatible with strip-cap formats.
4. Sealing: match the film to the readout
This is where a lot of avoidable failure happens. Films are not interchangeable:
- Optically clear qPCR films — required for real-time fluorescence. A translucent or aluminium seal will block or distort the optical path.
- Aluminium heat-seal films — excellent sealing for storage and endpoint work; not suitable where fluorescence must pass through.
- Breathable films — for cell culture and long-term low-temperature storage, where gas exchange matters.
- Low-temperature / heat-seal options — for workflows where the seal is applied under controlled heat.
Ask two questions: does light need to pass through it? and does gas need to pass through it? The answers determine the film.
5. Wall uniformity and heat transfer
For PCR tubes and plates, ultra-thin, uniform walls are the point of the product. Thicker or uneven walls change the rate at which heat reaches the reaction, which shifts Ct values and can make replicate wells disagree.
Uniform wall thickness is a manufacturing quality issue, not a design specification you can read off a datasheet — which is why the next section matters.
6. Instrument compatibility: verify by model
“Compatible with most real-time PCR instruments” is not a specification. The useful answer names models. Ask the supplier which platforms they have verified compatibility with, for example:
- ABI — 7500, QuantStudio
- Bio-Rad — CFX96
- Roche — LightCycler 480
- Eppendorf and other mainstream platforms
Then validate on your own instrument before committing to a volume order — see below.
7. Cleanliness: DNase/RNase-free is not optional
PCR is an amplification technique. Trace nuclease contamination destroys the result: DNase degrades template, RNase degrades RNA. For PCR consumables, require:
- DNase-free and RNase-free — stated as a release criterion, not a marketing phrase
- Pyrogen-free, typically endotoxin < 0.1 EU/mL
- No mold-release agents or colour additives, which can inhibit amplification
- Gamma irradiation to SAL 10⁻⁶ where sterile product is required
8. How to validate a new supplier without risk
The lowest-risk sequence:
- Request free trial samples of the specific formats you use.
- Ask for plates or strips to be sent for on-instrument testing — run them on your own instrument before any production order.
- Compare Ct consistency across the plate, not just whether the reaction worked. A plate can amplify correctly and still be unusable if well-to-well variation is high.
- Only then place a volume order, and keep the CoA for that batch on file.
Frequently asked questions
Are BUNSEN PCR plates SBS standard? Yes — the 96-well and 384-well plates are manufactured to the SBS footprint in non-skirted, semi-skirted and fully skirted formats.
Which is better, 0.1 mL or 0.2 mL PCR tubes? It depends on reaction volume and instrument. 0.2 mL is the most widely supported default; 0.1 mL suits low-volume reactions and instruments designed for it.
Can I use an aluminium seal for qPCR? No. Real-time fluorescence has to pass through the seal, so an optically clear qPCR film is required. Aluminium seals are for storage and endpoint work.
Do BUNSEN PCR consumables work with ABI, Bio-Rad and Roche instruments? They are verified compatible with mainstream platforms including ABI (7500 / QuantStudio), Bio-Rad (CFX96) and Roche (LightCycler 480). Because heat-transfer behaviour depends on the instrument’s block, trial samples can be supplied for on-instrument testing before a production order.
Are the plates supplied sterile? PCR consumables are supplied DNase-free and RNase-free as a release criterion, with gamma irradiation to SAL 10⁻⁶ available where sterile product is required.
Related BUNSEN products
- PCR plates (96 / 384-well, non / semi / fully skirted, SBS standard)
- PCR tubes (0.1 / 0.2 mL, single tubes and 8 / 12-tube strips)
- Sealing films (clear qPCR, aluminium, breathable, low temperature)
- Microcentrifuge tubes (1.5 / 2.0 mL, RNase/DNase/pyrogen-free, 25,000×g)
- Product Center — all BUNSEN lab consumables & instruments
BUNSEN PCR consumables follow SBS international standards, are released DNase-free and RNase-free, and are verified compatible with ABI (7500 / QuantStudio), Bio-Rad (CFX96) and Roche (LightCycler 480).
Browse the full product range, or request a sample or quotation.
Note: The information on the scientific research products above is for reference only!